IAM
\ Angle
|
0o
|
10o
|
20o
|
30o
|
40o
|
50o
|
60o
|
70o
|
80o
|
90o
|
|
Kq
(longitudinal)
|
1.0
|
1.0
|
0.99
|
0.98
|
0.96
|
0.93
|
0.87
|
0.74
|
0.38
|
0
|
|
Kq
(transversal)
|
1.0
|
1.02
|
1.08
|
1.18
|
1.37
|
1.4
|
1.34
|
1.24
|
0.95
|
0
|
(SPF report C632LPEN)
For longitudinal insolation, a value for 50o is generally only provided, however the curve is standard for most collectors, very similar to the transversal curve for flat plate collectors (see graph below).
![]() |
To
understand how the tubes passively track the sun
throughout the day, refer to the diagram to the
left.
When looking at the tubes from above (0o) each tube's surface is clearly visible, and therefore exposed to the maximum amount of sunlight. At this angle however some light is lost between the tubes, and therefore because this is used as a reference point for the IAM value of 1, when the gaps close up, the IAM value with actually increase (a greater % of light shining on the collector is actually being absorbed). When the sun reaches an angle of 40o which correlates to 2h 40min before or after midday, the solar tubes are still fully visible with no gaps between, and no overlap. It is at this point that the pure IAM values reach their peak. The tubes are exposed to all the sunlight shining towards them, and all the tubes are still perpendicular to the sun. |
As the angle increases, the tubes start to overlap, shading each other. They are still facing the sun, but the actual surface area of absorber exposed to the sunlight is reduced. Only a small amount of sunlight falls beyond 40o (early morning and late afternoon), and so this decrease in surface area has minimal influence on the total daily energy output of the collector.
The IAM effect increases the heat output of the Apricus solar collector by as much as 25% when compared to a flat collector surface of the same absorber area and performance variables. It is very important to consider IAM effect when calculating the heat output of Apricus solar collectors and indeed when comparing to other solar collectors.
Surprisingly, the Apricus solar collector actually provides more heat in a stationary position, than if it physically tracked the sun throughout the day!